0.5L 1L 2L 3L 5L Aluminium-Foil Multi-Layer Gas Sampling Bag

Warranty: None
Disposable: Disposable
Certification: ISO
Material: Plastic
Bottle Top: Screw Top
Capacity: 10ml
Gold Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
Aluminium-foil Multi-layer
Volume Could Supply
0.5L,1L,2L,3L,4L,5L,8L,10L,15L,20L,30L
Lead Time (Days)
About 15 Workdays If Quantity More Than 5000PCS
Valve Type
PC Stopcock Straight Valve
Shipping by
DHL or FedEx
Single Gross Weight
0.005 Kg
Transport Package
Carton
Specification
1L
Trademark
toplsbios
Origin
China
HS Code
7612909000
Production Capacity
100000PCS/Year

Product Description

Aluminium-foil Multi-layer Gas Sampling Bags
 

Aluminium-foil Multi-layer film is composite made of nylon membrane(PA),aluminum foil(AL)and polyethylene film(PE)with two-component adhesive,it is excellent alternative of rubber laner tube.It can be used for light sensitive gas samples preservation,mainly used for conventional analysis of sampling,filling stable chemical properties gas,e.g.,oil cracking gas,natural gas,coal bed gas,smoke gas,ambient atmosphere,technological process reaction gas and inorganic gas such as nitrogen hydrogen oxygen argon gas.

 



Features

 

•excellent physical strength and chemical inertness

•no transparent,low adsorption and low permeability and air-tightness

•convenient to collect and store gas samples

•the bag is of plastic valve or metal valve,filling gas displacement is convenient; unique high-elastic tensile rubber sample pad is dedicated to needle sampling

•widely used in petrochemical industry, environmental protection and scientific research institutes

Standard Aluminium-foil(Multi-layer)Gas Sampling Bag Sizes:0.5L,1L,2L,3L,4L,5L,8L,10L,15L,20L,30L, 40L~6000L or customized size.

Aluminium-foil (Multi-layer) film gas sampling bag is excellent alternative of rubber laner tube, it is composite made of nylon membrane(PA),aluminum foil(AL)and polyethylene film(PE)with two-component adhesive.It can be used for light sensitive gas samples preservation,mainly used for conventional analysis of sampling,filling stable chemical properties gas,e.g.,oil cracking gas,natural gas,coal bed gas,smoke gas,ambient atmosphere,technological process reaction gas and inorganic gas such as nitrogen hydrogen oxygen argon gas.


Operating guide & Precautions:

• Avoid filling pressure higher than 6000Pa. Fill gas until the bag is fully expanded, however, it is not so tense when you press it using your finger.The overpressure filling can cause gas sampling bag burst damage.

• Operating temperature: -15ºC~+60ºC.

• Keep away from flame and high temperature when filling and storage. Avoid contacting sharp stuff.

• Before use, flush sampling bags three times with the gas you want to fill.

• The connection of valve and instrument or the equipment best be adopted correspongding latex tube or silicone tube transition.

• For sulphide and halogen gas ,high content such as the percentage level or low content such as PPM level are not recommended to use

• As the composite membrane using two-component adhesive when composition,it can volatilize benzene, ketones, ethers, esters and other organic matter,So we should pay attention to the Aluminium-plastic composite membrane separating out the residual organic matter can pollute the sampling gas inside the bag,analysis data can cause interference.

• The gas sampling bag should be cleaned repeatedly replacement if it is reused. Suggest the same sample bag collecting samples of the same kind gas, don't mix

• The sample gas in sampling bag to save time should not be too long,specific saving time depend on detection limit of experimental analysis requirement,gas component species,temperature and humidity,pressure,etc:generally,for pure inert gas,sampling bag can be used as a temporary storage container and recommended storage time less than 72 hours;for standard gas,flue gas,ambient atmosphere,recommended storage time less than 24 hours.

• High purity nitrogen gas heating replacement can reduce the interference of organic deposition

• When sampling and cleaning,please do not exceed 80% of the calibration volume,take 1L sampling bag for example,suggest sampling volume is less than 0.8 L.

• There must be a blank sample compare for precise experimental analysis to do background deduction.

• For high-temperature high-pressure gas should be down to normal temperature and pressure to sample,specific treatment method according to actual situation.

• For negative pressure gas, should be sampled by appropriate power and flow rate vacuum pump.

• For the gas containing particulate matter,dust and aerosols,should adopt filter to prevent polluting the sample bag,then difficult to clean.



 





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Trading Company
Main Products
Laboratory Accessories
Number of Employees
3